Hioki 80 V - 600 V AC Premier Pocket Digital MultiMeter, DT4221

Shop all Hioki

SKU: ME.EL.MU.00036

Model: DT4221

Roll over the image to zoom in


Key Features

  • Product Type: Multimeter
  • Weight: 190 g
  • Power supply: LR03 Aalkaline Batteries
  • DC Voltage Range: 600.0 mV to 600.0 V, 4 Ranges
  • AC Voltage Range: 6.000 V to 600.0 V, 3 Ranges
  • Voltage Detection: 80 V to 600 V AC
See all product information

ToolBuy Benefits

₹9,651 (Incl. of all taxes)

₹8,179 + ₹1,472 GST (18%)

MRP was MRP ₹9,622

Save 15%



5 Business Days

1

9030

Download Product LeafletNot available
Download Hioki CatalogueNot available

Highlights

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level.

The DT4221 is a pocket-sized digital multimeter designed specifically for electrical work requiring optimal safety, with ±0.5% DC V accuracy and wide 40 Hz to 1 kHz AC V bandwidth.
 
  • Display: Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
  • Display refresh rates: 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s)
 

Key Features:

  • Achieving a high level of safety in a compact body and lightweight design
  • Robust design capable of withstanding a drop from a height of 1 m
  • Broad -10°C to 50°C (14°F to 122°F) operating temperature range
  • Resistance and diode testing functions omitted by design in pursuit of added safety (DT4221)
  • ±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
  • Voltage detection function (DT4221)
  • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)

 

What's Included In This Package:

  • 1x Test lead DT4911
  • 1x Holster
  • 1x Instruction manual
  • 1x LR03 alkaline battery
 

Compact and safety-designed digital multimeter for voltage measurement

Voltage detection function

Compact and lightweight design for outstanding ease of use

The small form factor fits in your hand perfectly and is easily stowable, making it convenient to transport to and from the field and boosting work efficiency.

Use Single AAA alkaline battery only

Since the DT4221 only uses a single AAA alkaline battery that can be easily replaced, there’s no need to carry a large number of spare batteries with you.

Rear probe connections for superior screen visibility and easy storage

Accurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function.

Measure output voltage on the secondary sides of inverters by eliminating harmonic components

The easily visible exposed tubular side vials are designed to offer consistent accuracy in the measurements. The exposed nature makes it easy to read the measurements from both sides.

True RMS measurement for accurate measurement of even distorted current waveforms

Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.

Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind

All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.

Safe measurement requires use of an instrument that suits the measurement location

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident. Despite a compact body, the DT4221 can be used to measure voltage at distribution panels.

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for Hioki 80 V - 600 V AC Premier Pocket Digital MultiMeter, DT4221
Power supplyLR03 Aalkaline Batteries
DC Voltage Range600.0 mV to 600.0 V, 4 Ranges
DC Voltage Range (Basic Accuracy)±0.5 % rdg. ±5 dgt.
AC Voltage Range6.000 V to 600.0 V, 3 Ranges
AC Voltage Range (Basic Accuracy 40 - 500 Hz)±1.0 % rdg. ±3 dgt. (True RMS, Crest Factor 3)
Frequency RangeAC V Measurement: 99.99 Hz (5 Hz or More) to 9.999 kHz, 3 Ranges
Frequency Range (Basic Accuracy)±0.1 % rdg. ±2 dgt.
Frequency Characteristics40 Hz - 1 kHz
Continuity Check (Continuity Threshold [ON])25 Ohm or Less (Buzzer Sound)
Continuity Check (Continuity Threshold [OFF])245 Ohm or More Response Time: 0.5 ms or More
Voltage Detection80 V to 600 V AC
Battery UsageContinuous Use 40 hours (Backlight OFF)
Length x Width X Height72 mm x 149 mm x 38 mm