Kusam-Meco 0oC - 50oC Thermocouple Calibrator, KM-CAL-802

Shop all Kusam-Meco

SKU: ME.EL.PR.00096

Model: KMCAL802

Roll over the image to zoom in


Key Features

ToolBuy Benefits

₹25,299 (Incl. of all taxes)

₹21,440 + ₹3,859 GST (18%)

MRP was MRP ₹26,800

Save 20%



3 Business Days

1

90303390

Download Product LeafletNot available
Download Kusam-Meco CatalogueNot available

Highlights

This is a Thermocouple “Source” & ”Sink” Calibrator. It gives an output of DC Volts & output for R, S, B, E, K, J, T & N Thermocouples. It measures DC Voltage & also R, S, B, E, K, J, T & N Thermocouples. It has 5 5-digit LCD display & extremely high accuracy of 0.05%.



Technical Data:

Output Function
Output Range Output Range Resolution Accuracy Remarks
DC Voltage 100mV -10.00 ~ 110.00mV 0.01mV ±0.05% ± 30µV The max. Output current ± 2mA
1V -0.1000 ~ 1.1000V 0.1mV ±0.05% ± 30mV
Thermocouple R -40 ~ 1760°C 1°C
  • ±0.05% + 3(Less than or equals to 100°C)
  • ±0.05% + 2(more than 100°C)
Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force.
S -20 ~ 1760°C 1°C
RTD B 400 ~ 1800°C 1°C
  • ±0.05% + 3(Less than or equals to 600°C)
  • ±0.05% + 2(more than 600°C)
E -200.0 ~ 1000.0°C 0.1°C
  • ±0.05% + 20 (Less than or equal to -100°C)
  • ±0.05% + 10 (More than -100°C)
K -200.0 ~ 1370°C
J -200.0 ~ 1200.0°C
T -200.0 ~ 400.0°C
N -200.0 ~ 1300.0°C

Input Function
Output Range Output Range Resolution Accuracy Remarks
DC Voltage DCmV 100mV -10.00 ~ 110.00mV 0.01mV ±0.05% ± 3 Input Resistance: 1MΩ
Thermocouple TC R -40°C ~ 1760°C 1°C
  • ±0.05% + 3 (Less than or equal to 100°C)
  • ±0.05% + 2 (More than 100°C)
  • Input Resistance: 1MΩ
  • Employs ITS-90 temperature standard The accuracy does not include the error of interior temperature compensation sensor The accuracy does not include the impact of interior thermoelectric force.
S -200°C ~ 1760°C
B 400°C ~ 1800°C
  • ±0.05% + 3(Less than or equals to 600°C)
  • ±0.05% + 2(more than 600°C)
E -200.0°C ~ 1000.0°C 0.1°C
  • ±0.05% + 20 (Less than or equal to -100°C)
  • ±0.05% + 10 (more than -100°C)
K 200.0°C ~ 1370°C
J -200.0°C ~ 1200.0°C
T -200.0°C ~ 400.0°C
N -200.0°C ~ 1300.0°C



Specification:

Display 5 Digit LCD Display
Max. Allowable Voltage 30V
Operating Temperature 0 ~ 50°C
Operating Humidity Less Than Equal To 80% RH
Storage Temperature Less Than Equal To -10°C ~ 55°C
Storage Humidity Less Than Equal To 90% RH
Temperature Coefficient 0.1x(Dedicated Accuracy)%/°C (5°C ~ 18°C, 28°C ~ 40°C)
Power Consumption About 50m/3V
Dimension (LxWxD) 180 x 90 x 47 mm



Safety:

  • Complies with IEC1010 (safety standard issued by International Electrician Committee)


Package Content:

  • User Manual
  • Test lead CF-36 (Clips for probe)
  • Holster 
  • Carrying case

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for Kusam-Meco 0oC - 50oC Thermocouple Calibrator, KM-CAL-802
Basic Accuracy± 0.05%

Shop By Related Categories