Key Features

  • Product Type: Multimeter
  • Weight: 455 g
  • Display (LCD): 6000 counts, updates 3/sec
  • Battery Type: 2 AA, IEC LR6
  • Battery life: 500 hours minimum
  • Ingress Protection: IP40
  • Altitude: Operating 2000 Mtr; Storage 12000 Mtr
See all product information

ToolBuy Benefits

₹12,687 (Incl. of all taxes)

₹10,752 + ₹1,935 GST (18%)

MRP was MRP ₹15,812

Save 32%



3 Business Days

1

90303100

Download Product LeafletNot available
Download Fluke CatalogueNot available

Highlights

Fluke 17B MAX Inherits and continues the classic design of 17B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.

Features:

  • Audible and visual alarm for incorrect connections
  • Test leads with fines tips for circuit board testing
  • Simple interface to wake meter from sleep mode by activating any buttons
  • Voltage: 6000-count reading
  • Capacitance range: 2000uF
  • Safety rating: CATIII 600V
  • Frequency and temperature measurement


What's Included In This Package:

  • TL31 Extra-Slim Test Leads with 2 Protective Caps
  • Type K Thermocouple
  • 2 AA Batteries
  • Safety information


Accuracy Specifications:

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).

Function Range Resolution Accuracy
15B MAX 17B MAX
AC Volts (40 Hz to 500 Hz)1 6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3 1.0 % + 3
AC Millivolts 600.0 mV 0.1 mV 3.0 % + 3 3.0 % + 3
DC Volts 6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 3 0.5 % + 3
DC Millivolts 600.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
AC Current μA (40 Hz to 400 Hz)2 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3 1.5 % + 3
AC Current mA (40 Hz to 400 Hz)2 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3 1.5 % + 3
AC Current A (40 Hz to 400 Hz)2 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3
DC Current μA2 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3 1.5 % + 3
DC Current mA2 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3 1.5 % + 3
DC Current A2 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3
Diode Test3 2.000 V 0.001 V 10% 10%
Temperature 4 50.0 °C to 400.0 °C
0 °C to 50.0 °C
-55.0 °C to 0 °C
0.1 °C NA 2 %+1 °C
2 °C
9 %+2 °C
Resistance (Ohms)5 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance6 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
2000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1 (10 Hz to 100 kHz) 50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA 0.1 % + 3
Duty Cycle1 1% to 99% 0.10% NA 1 % typical7
Continuity Threshold 70Ω 70Ω
Backlight Yes Yes
  • All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  • Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
  • Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
  • Use Type K thermocouple
  • Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
  • Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
  • Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.

 

Input Characteristics
Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection Ratio
AC Volts 1000 V 1 >10 MΩ, <100 pF >60 dB at 50 Hz or 60 Hz
AC Millivolts 1000 V 1 >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
DC Volts 1000 V 1 >10 MΩ, <100 pF >100 dB at 50 Hz or 60 Hz >60 dB at 50 Hz or 60 Hz
DC Millivolts 1000 V 1 >1 MΩ, <100 pF >80 dB at 50 Hz or 60 Hz
1106 V Hz max

 

General Specifications:
Temperature Operating 0 °C to 40 °C;
Storage -30 °C to 60 °C
Relative Humidity Operating Humidity Non-condensing
(<10 °C); ≤90 % RH at 10 °C to 30 °C;
≤75 % RH at 30 °C to 40 °C
Fuse protection for current inputs 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow


Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for Fluke 17B Max-02 6000 Counts / 600V Digital Multimeter With TL31 Extra-Slim Test Leads
Maximum voltage between any Terminal and Earth Ground600 V
Maximum differential voltage between V and COM terminals1000V
Display (LCD)6000 counts, updates 3/sec
Battery Type2 AA, IEC LR6
Battery life500 hours minimum
Ingress ProtectionIP40
Electromagnetic EnvironmentIEC 61326-1: Portable
Size (HxWxL)183 mm x 91 mm x 49.5 mm
Operating Humidity, 40 M Ohms range=80 % RH at 10 °C to 30 °C; =70 % RH at 30 °C to 40 °C
AltitudeOperating 2000 Mtr; Storage 12000 Mtr
Temperature Coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
SafetyIEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2