- Product Type: Multimeter
- Weight: 624 g
- Operating temperature: –20 °C to + 55 °C
- Storage temperature: –40 °C to + 60 °C
- Operating Altitude: 2000 Mtr
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹48,857 (Incl. of all taxes)
₹41,404 + ₹7,453 GST (18%)
MRP was MRP ₹60,888
Save 32%
12 Business Days
1
90303100
Download Fluke CatalogueNot available
Highlights
The Fluke 87V TRMS Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high altitude locations. This digital multimeter takes the guesswork out of drive system troubleshooting. This electrical multimeter includes a unique function for accurately measuring noisy at the VFD and at the motor terminals.
Special shielding blocks high frequency, high-energy noise generated by large drive systems. The Fluke 80 Series V of digital multimeters have improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment.
Features:
The Fluke 87V industrial digital multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment.- Safer and rugged: Safety rated CAT III 1000 V, CAT IV 600 V
- Accurate: Measure current, voltage and frequency on complex variable frequency drive (VFD) signals
- This electrical multimeter correctly measure pulse-width modulated motor drive signals
- Save time: The 87V multimeter includes a built-in thermometer and temperature probe
- True-RMS AC voltage and current for measuring non-linear signals
Other Useful Features:
- Rugged, high accuracy industrial electrical multimeter to measure current, voltage and frequency on complex variable frequency drive (VFD) signals
- Offers true-RMS AC voltage and current for measuring non-linear signals
- Captures intermittents as short as 250 µS
- Safety rated CAT III 1000 V, CAT IV 600 V
- Includes a built-in thermometer and temperature probe
Applications:
- For Application engineer / Plant engineer / Industrial electricians (Working with VSD’s) / Electrical engineer.
- In plant automation, Power distribution, Electro-mechanical equipment,
- Industrial electronics, Setting up / repairing, adjustable speed motor drives.
What's Included In This Package:
- Fluke 87V Industrial Multimeter
- TL75 Test Leads (TL175 Eur)
- AC175 Alligator Clips
- Holster with tilt-leg, test lead storage
- 80BK Temperature Probe
- 9V Battery (Installed)
Specifications:
| Voltage DC | Maximum voltage | 1000 V |
| Accuracy | ±(0.05% + 1) | |
| Maximum resolution | 10 µV | |
| Voltage AC | Maximum voltage | 1000 V |
| Accuracy | ±(0.7% + 2) True RMS | |
| AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
| Maximum resolution | 0.1 mV | |
| Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Amps accuracy | ±(0.2% + 2) | |
| Maximum resolution | 0.01 µA | |
| Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Amps accuracy | ±(1.0% + 2) True RMS | |
| Maximum resolution | 0.1 µA | |
| Resistance | Maximum resistance | 50 MΩ |
| Accuracy | ±(0.2% + 1) | |
| Maximum resolution | 0.1 Ω | |
| Capacitance | Maximum capacitance | 9,999 µF |
| accuracy | ±(1% + 2) | |
| Maximum resolution | 0.01 nF | |
| Frequency | Maximum frequency | 200 kHz |
| Accuracy | ±(0.005% + 1) | |
| Maximum resolution | 0.01 Hz | |
| Duty cycle | Maximum duty cycle | 99.9% |
| Accuracy | ±(0.2% per kHz + 0.1%) | |
| Maximum resolution | 0.1% | |
| Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
|
| 80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
|
| Conductance | Maximum conductance | 60.00 nS |
| Accuracy | ±(1.0% + 10) | |
| Maximum resolution | 0.01 nS | |
| Diode | Range | 3 V |
| Resolution | 1 mV | |
| Accuracy | ±(2% + 1) | |
| Duty cycle range | Accuracy | Within ±(0.2% per kHz + 0.1%) |
Please Note that Products may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| Operating temperature | –20 °C to + 55 °C |
|---|---|
| Storage temperature | –40 °C to + 60 °C |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) / 0% – 70% (35 °C – 55 °C) |
| Operating Altitude | 2000 Mtr |
| Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
| Agency approvals | CE, CSA, RCM |
| Size | 201 x 98 x 52 mm (with holster) |
| Digital Display | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
| Analog Display | 32 segments, updates 40/sec |
| Display Frequency | 19,999 counts, updates 3/sec at > 10 Hz |
| Warranty | Lifetime |
| Battery Life | Alkaline ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010–1:2001 |