V&A Instrument -10°C ~ 55°C RTD Process Calibrator, VA720

Shop all V&A Instrument

SKU: ME.EL.PR.00123

Model: VA720

Roll over the image to zoom in


Key Features

  • Product Type: Process Calibrators
  • Weight: 472 g
  • Operating Temperature: -10°C ~ 55°C
  • Storage Temperature: -40°C ~ 60°C
See all product information

ToolBuy Benefits

₹20,060 (Incl. of all taxes)

₹17,000 + ₹3,060 GST (18%)

MRP was MRP ₹20,000

Save 15%



7 Business Days

1

Download Product LeafletNot available
Download V&A Instrument CatalogueNot available

Highlights

RTD Calibrator is a exactitude measurement and source instrument, it can be use to calibrate the RTD* transmitter (include most impulse transmitter). RTD Calibrator can measure or simulate 7 difference types of RTD (? or?), and measure or simulate the Resistance. But it could not use to measurement or source at a same time.


Features:

  • Maximum voltage applied between any jack and earth ground or between any tow jack: 30V
  • Temperature coefficient: ±0.01%/°C on 0°C~18°C and 28°C~50°C
  • Relative humidity: 95% up to 30°C, 75% up to 40°C, 45% up to 50°C, 35% up to 55°C
  • RTD Process Calibrator is an exactitude measurement and source instrument, it can be used to calibrate the RTD* transmitter (including most impulse transmitters).


Maintenance:

Cleaning Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents.
Calibration Calibrate your calibrator once a year to ensure that it performs according to its specifications.
Replacing the Battery
  • Please change the battery when the LCD indicates
  • Turn off the power of the Calibrator, When you change the battery, and screw off the breechblock on the battery cabinet cover, then take off it and instead the fresh AAA 1.5V battery.


Package Content:

  • 1x Calibrator
  • 2x Pair of test leads and alligator clips
  • 6x AAA 1.5V battery
  • 1x user’s manual

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for V&A Instrument -10°C ~ 55°C RTD Process Calibrator, VA720
Operating Temperature-10°C ~ 55°C
Storage Temperature-40°C ~ 60°C
ResolutionRTD 0.1°C/°F (Resistance - 0.01/0.1O)
Operating Altitude3000 Meters (max.)
ShockRandom 2g , 5Hz to 500Hz
Safety1 Meter Drop Test
Range0.00 ~ 3200.0 Ohm or -200.0 ~ 630.0°C
Temperature Accuracy±0.2°C (Resolution - 0.1°C)
Resistance Accuracy±0.2 Ohm (Resolution - 0.1 Ohm)
DisplayLarge 5 Digit LCD
LCD Size64 × 42 mm
Power Supply6 x AAA 1.5V Battery
Dimension (mm)205 × 98 ×46 mm

Shop By Related Categories