Fluke 353 2000A True-RMS AC / DC Clamp Meter

Shop all Fluke

SKU: HA.AU.CL.00016

Model: Fluke353

Roll over the image to zoom in


Key Features

  • Product Type: Clamp Meters
  • Weight: 814 g
  • Range: 40 A / 400 A / 2000 A / 1400 AC RMS
  • Test leads: Rated to 1000 V
  • Jaw size: 58 mm (2.28 in)
See all product information

ToolBuy Benefits

₹1,14,531 (Incl. of all taxes)

₹97,060 + ₹17,471 GST (18%)

MRP was MRP ₹1,42,736

Save 32%



12 Business Days

1

90275090

Download Product LeafletNot available
Download Fluke CatalogueNot available

Highlights

Confidently take reliable readings with the True RMS, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications.

The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.


Features:

  • Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings.


What's Included In This Package:

  • Fluke 325 True-RMS Clamp Meter
  • TL75 Test Leads
  • Type K Thermocouple
  • Two AAA Batteries (Installed)
  • Soft Case


Electrical Specifications:

Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC RMS
Resolution 10 mA / 100 mA / 1 A
Accuracy A: 1.5% rdg + 15 digits
A: 1.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC RMS
Crest Factor1 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC RMS
Resolution 10 mA / 100 mA / 1 A
Accuracy 10 A: 3.5% rdg + 15 digits
10 A: 3.5% rdg + 5 digits
Trigger level for Inrush 0.50 A / 5.0 A / 5 A
Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A
Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2% + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5% + 5 counts
Trigger level Refer to current and voltage tables
1. Add 2% to error spec for CF > 2

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision.

Specifications

Technical specifications for Fluke 353 2000A True-RMS AC / DC Clamp Meter
Range40 A / 400 A / 2000 A / 1400 AC RMS
Resolution10 mA / 100 mA / 1 A
Test leadsRated to 1000 V
Jaw size58 mm (2.28 in)
Operating temperature32°F to +122°F (0°C to +50°C)
Storage temperature-4°F to 140°F (-20°C to +60°C)
Operating humidity0 to 95% (non-condensing)
Operating altitude2000 Mtr
Storage altitude10,000 Mtr
IP rating42 (indoor use only)
Drop test requirements1 Mtr
Temperature coefficients Current0.1% of reading per °C outside 22°C to 24°C
Temperature coefficients Voltage0.1% of reading per °C outside 22°C to 24°C
BatteriesSix 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)100 hours
Dimensions (L x W x D)300 x 98 x 52 mm (12 x 3.75 x 2 in)
Safety ratingIEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
EMI, RFI, EMCFCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325

Shop By Related Categories