Fluke 374 600A True-RMS AC / DC Clamp Meter
Roll over the image to zoom in
Key Features
- Product Type: Clamp Meters
- Range: 600.0 A
- Resolution: 0.1 A
- AC Current Range: 2500 A
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹34,939 (Incl. of all taxes)
₹29,609 + ₹5,330 GST (18%)
MRP was MRP ₹43,542
Save 32%
3 Business Days
1
90303100
Download Fluke CatalogueNot available
Highlights
The Fluke 374 True RMS Clamp Meter can read up to 600 V and 600 A in both AC and DC modes. Additionally, the 374 is compatible with the new iFlex flexible current probe (sold separately), which increases the measurement range to 2500 A AC and provides increased display flexibility, and improved wire access.
Features:
- iFlex flexible current probe (sold separately) expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access
- CAT IV 600 V, CAT III 1000 V
- Propietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Three-year warranty
- Soft carrying case
What's Included In This Package:
- Coated instruction card
- Safety information sheet
- Soft carrying case
- TL75 test leads
- Two AA Alkaline batteries
Specifications:
| Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error |
| A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% |
| B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% |
| C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | |||
| Trigger Level | 5 – 10 Hz, ≥10 A | ||
| 10 – 100 Hz, ≥5 A | |||
| 100 – 500 Hz, ≥10 A | |||
| Frequency via Flexible Current Probe | |||
| Range | 375 and 376 | 5.0 - 500.0 Hz | |
| Resolution | 0.1 Hz | ||
| Accuracy | 0.5% ± 5 digits | ||
| Trigger Level | 5 – 20 Hz, ≥ 25 A | ||
| 20 – 100 Hz, ≥ 20 A | |||
| 100 – 500 Hz, ≥ 25 A | |||
| Resistance | |||
| Range | 374 375 and 376 |
6000 Ω 60 kΩ |
|
| Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
|
| 375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
||
| Accuracy | 1% ± 5 digits | ||
| Capacitance | |||
| Range | 1000 μF | ||
| Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
||
| Accuracy | 1% ± 4 digits | ||
| Mechanical Specifications | |||
| Size (L x W x H) | 246 mm x 83 m x 43 mm | ||
| Weight | 388 g | ||
| Jaw Opening | 34 mm | ||
| Flexible Current Probe Diameter | 7.5 mm | ||
| Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | ||
| Environmental Specifications | |||
| Operating Temperature | 10°C – +50°C | ||
| Storage Temp | -40°C – +60°C | ||
| Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
||
| Operating Altitude | 3000 meters | ||
| Storage Altitude | 12,000 meters | ||
| EMC | EN 61326-1:2006 | ||
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
||
| Safety Specifications | |||
| Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
||
| Agency Approvals | |||
| Batteries | 2 AA, NEDA 15A, IEC LR6 |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision.
Specifications
| Range | 600.0 A |
|---|---|
| Resolution | 0.1 A |
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) 2.5% ±5 digits (100-500 Hz) |
| Crest Factor (50 Hz/60 Hz) | 2.5 @ 600 A Add 2% for C.F. >2 |
| AC Current Range | 2500 A |
| AC Current Resolution | 0.1 A (= 600 A) 1 A (= 2500 A) |
| AC Current Accuracy | 3% ±5 digits (5 – 500 Hz) |
| DC Current Range | 600.0 A |
| DC Current Resolution | 0.1 A |
| DC Current Accuracy | 2% ±5 digits |
| AC Voltage Range | 1000 V |
| AC Voltage Resolution | 0.1 V (=600.0 V) 1 V (=1000 V) |
| AC Voltage Accuracy | 1.5% ±5 digits (20 Hz to 500 Hz) |
| DC Voltage Range | 1000 V |
| DC Voltage Resolution | 0.1 V (=600.0 V) 1 V (=1000 V) |
| DC Voltage Accuracy | 1% ±5 digits |
| mV dc Range | 500.0 mV |
| mV dc Resolution | 0.1 mV |
| mV dc Accuracy | 1% ±5 digits |
| Resistance Range | 6000 |
| Resistance Resolution | 0.1 O (=600 O) 1 O (=6000 O) |
| Resistance Accuracy | 1% ±5 digits |
| Capacitance Range | 1000 μF |
| Capacitance Resolution | 0.1 μF (= 100 μF) 1 μ F (= 1000 μF) |
| Capacitance Accuracy | 1% ±4 digits |