- Product Type: Clamp Meters
- Weight: 410 g
- Storage temperature: -25 to 60oC
- Operating altitude: 0 to 2000 m
- Vibration: Random 2 g, 5 to 500 Hz
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹1,24,603 (Incl. of all taxes)
₹1,05,596 + ₹19,007 GST (18%)
MRP was MRP ₹1,55,288
Save 32%
30 Business Days
1
90303100
Download Fluke CatalogueNot available
Highlights
The Fluke 772 loop meter adds to the basic capabilities of the Fluke 771 to save more time and expand its applications. With the 771, you'll also be able to: source and simulate 4-20 mA signals for testing control system I/O; measure 4-20 mA signals with in-circuit measurement; power a transmitter with the 24 V loop power supply; and automatically ramp and step change the 4-20 mA output for remote testing.
You'll be able to test 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down, which can save you time, and help you avoid possibly missing something going on in the process.
Features:
- Loop meter that measures 4 to 20 mA signals without breaking the loop
- Features best in class 0.2% accuracy
- Simultaneously measures the mA signal with the clamp and sources a mA signal
- Delivers 0.01 mA resolution and sensitivity
- Measures mA signals for PLC and control system analog I/O
Other Useful Features:
- Simulates 4-20 mA signals for testing control system I/O
- Sources 4 to 20 mA signals for testing control system I/O or I/Ps
- Measures 4 to 20 mA signals with in-circuit measurement
- Includes simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Features a detachable clamp with extension cable for measurements in tight locations
- Captures and displays changing measurements with Hold function
- Offers mA output linear ramp or 25% step output
- Extends battery life with auto-off and backlight timeout
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight to illuminate hard to see wires in dark enclosures
- Measures 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically changes the 4 to 20 mA output for remote testing.
What's Included In This Package:
- Fluke 772 Milliamp Clamp Meter
- (1 pair) TL75 test leads
- AC72 detachable clip
- (1 pair) TL 940 mini hook test leads
- (4) AA alkaline batteries (installed)
- Soft carrying case
- Magnetic Hanging Strap
- Quick Reference Guide
Specifications:
| mA measurement (measured by clamp) |
Resolution / range | 0 to 20.99 mA |
| Accuracy | 0.2% + 5 counts | |
| Resolution / range | 21.0mA to 100.0 mA | |
| Accuracy | 1% + 5 counts | |
| mA measurement (measured in series with test jacks) | Resolution / range | 0 to 24.00 mA |
| Accuracy | 0.2% + 2 counts | |
| mA source (maximum mA drive: 24 mA into 1,000 ohms) | Resolution / range | 0 to 24.00 mA |
| Accuracy | 0.2% + 2 counts | |
| mA simulate (maximum voltage 50 V dc) | Resolution / range | 0 to 24.00 mA |
| Accuracy | 0.2% + 2 counts |
Please Note that Products may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| Diameter of measurable conductor | 0.177" or 4.5 mm max |
|---|---|
| Operating temperature | -10 to 50oC |
| Storage temperature | -25 to 60oC |
| Operating humidity | < 90% @ <30oC, < 75% @ 30 to 55oC |
| Operating altitude | 0 to 2000 m |
| IP rating | IP 40 |
| Size | 44 x 70 x 246 mm (2 7/8 x 5 3⁄4 x 11 5/8 in) |
| Vibration | Random 2 g, 5 to 500 Hz |
| Shock | 1 meter drop test (except the jaw) |
| EMI/RFI | Meets EN61326-1 |
| Temperature coefficient | 0.01% oC (< 18oC or > 28oC) |
| Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms |
| Warranty | Three years |