- Product Type: Electrical Testers
- Weight: 280 g
- Battery Type/Life: AAA (2); 40 hours
- AC Bandwidth: 45 Hz to 66 Hz
- Voltage Hazard LED: LEDs turn on at voltages > 30 V AC/DC ±35%
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹16,285 (Incl. of all taxes)
₹13,801 + ₹2,484 GST (18%)
MRP was MRP ₹20,296
Save 32%
2 Business Days
1
90303100
Download Fluke CatalogueNot available
Highlights
Safer than solenoid testers and fully compliant with NFPA 70E, (when used properly per Article 110.4 Use of Equipment (A) Test Instruments and Equipment), the T+Pro helps electricians and technicians work safer by indicating the presence of voltage, even when the batteries are dead.
Additional functionality, such as a GFCI trip, easy-to-read LCD screen, resistance measurement up to 9.99 k?, and a built-in flashlight make the T+Pro the first voltage tester that electricians reach for.
How To Use The Fluke T+ Pro Electrical Tester:
The Fluke T+Pro Electrical Tester indicated AC/DC voltage in three different ways: Light / Sound / Vibration
The user will be alerted to the presence of voltage in dark or noisy environments with the light and vibration notifications. And the audible indication can be optionally disabled at the push of a button.
Combine those features with the backlit LCD display function and it’s easier for users to see the screen in many hard-to-test areas. The included HOLD function will freeze the display for even easier reading in those areas.
Features:
- Detect live voltage, see voltage level, even with dead batteries
- 3 forms of AC/DC voltage indication: light, sound, and vibration
- Backlit LCD display and hold function for easier viewing
- The T+Pro is safety rated to CAT IV 600 V, CAT III 1000 V, and is CSA approved.
- The tester also has a built-in flashlight for highlighting the point of measurement.
- A GFCI trip is included for testing outlet GFCI circuits.
- The T+ Pro also includes a rotary field indicator and has convenient probe storage on the back.
- The product is protected by a two-year warranty.
Key Safety Features:
The T+Pro is safety rated to CAT IV 600 V, CAT III 1000 V, and is CSA approved. The tester also has a built-in flashlight for highlighting the point of measurement. A GFCI trip is included for testing outlet GFCI circuits.
The T+ Pro also includes a rotary field indicator and has convenient probe storage on the back. The product is protected by a two-year warranty.
What's Included In This Package:
- Fluke T+ Pro Electrical Tester
- Test lead wrap
- TP2 test probes
- Quick Reference Guide
Specifications:
| Temperature | Operating | -10°C to 55°C (14°F to 131°F) |
| Storage | -30°C to 60°C (-22°F to 140°F) | |
| Relative Humidity | 90% | 0°C to 30°C (32°F to 86°F) |
| 75% | 30°C to 40°C (86°F to 104°F) | |
| 45% | 40°C to 50°C (104°F to 122°F) | |
| Altitude | Operating | 2,000 m (approx. 6,561.6 ft) |
| Storage | 10,000 m (approx. 32,808.4 ft) | |
| Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV Compliance to NFPA 70E1 |
|
| Duty Cycle | Indefinitely for voltages up to 240 V | |
| For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off | ||
| For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s | ||
| LCD Accuracy | AC voltage | ±(3% rdg + 2 digits) |
| DC voltage | ±(2% rdg + 2 digits) | |
| Resistance | ±(5% rdg + 3 digits) | |
| LCD Resolution | 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V | |
| 0.01 kΩ for resistance measurement | ||
| 1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment. |
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| Battery Type/Life | AAA (2); 40 hours |
|---|---|
| AC Bandwidth | 45 Hz to 66 Hz |
| Shock, Vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument |
| Maximum Working Voltage | 1000 V AC/DC |
| Maximum Measurable Voltage | 600 V AC/DC |
| Voltage Hazard LED | LEDs turn on at voltages > 30 V AC/DC ±35% |
| LED Voltage Indication Levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V |
| GFCI Test Current | 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA |
| Standard Input Test Current | < 5 mA |