Key Features

  • Product Type: Multimeter
  • Weight: 635 g
  • Update Rate: 5 Per Second Nominal
  • Operating Temperature: -10oC ~ 40oC
See all product information

ToolBuy Benefits

₹35,707 (Incl. of all taxes)

₹30,260 + ₹5,447 GST (18%)

MRP was MRP ₹37,825

Save 20%



3 Business Days

1

90303100

Download Product LeafletNot available
Download Kusam-Meco CatalogueNot available

Highlights

  • VFD V & Hz readings
  • Paper White Backlight LCD Display
  • Record MAX / MIN readings
  • Display Hold Function
  • Dual Digital Display
  • Autoranging
  • Auto Power Off
  • LOCK-Test mode for Insulation Resistance & Earth Continuity Test
  • BeepJack TM audible & visible input warning
  • Remote Probe for Insulation Resistance & Earth Continuity Test
  • Functions: DC/AC Voltage, VFD AC Voltage, AC / DC mV, AC / DC mA, Insulation Resistance, Resistance, Capacitance, Earth Continuity Test, Hz Line Level Frequency, Temperature
  • Auto or Manual-ranging mode.
  • Earth Continuity Test: 110mA @20 Ω range, 220mA @2.0 Ω range. The tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on & 25 seconds off.
  • Relative Humidity: Maximum relative humidity 90% for temperature up to 28°C decreasing linearly to 50% relative humidity at 40°C
  • Temperature Coefficient: Nominal 0.15 x (specified accuracy)/ °C @(-10°C~18°C or 28°C~40°C), or otherwise specified


Insulation Resistance @ 1mA Test Current:

  • 50V output Voltage: 25mA
  • 100V output Voltage: 45mA
  • 250V output Voltage: 85mA
  • 500V output Voltage: 170mA
  • 1000V output Voltage: 440mA
  • Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature.
  • These are standard tests of 1000V into 1MΩ with a duty cycle of 5 seconds on and 25 seconds off.


Safety:

  • Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to CAT III 1000 V AC & DC and CAT IV 600V AC & DC
  • Compliance to IEC/EN61557; 2007 (per CE requirements, not certified by UL or ETL): IEC/EN61557-1, IEC/EN61557-2 & IEC/EN61557-4 where applicable.
  • E.M.C: Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11) In an RF field of 3V/m: Total Accuracy = Specified Accuracy + 25 digits. Performance above 3V/m is not specified.
  • Transient Protection: 8KV(1.2/50µS Surge)
  • Overload Protections: Insulation Resistance & mA : 0.4A/1KV, IR 30kA or better / Earth Continuity Test: 0.25A/1KV, IR 30kA or better / V: 1100Vrms / mV, Ω & Others: 1000 Vrms


Package Content:

  • Test probe pair
  • BRP21S2-C Remote probe
  • Alligator clip pair
  • Holster
  • User manual
  • Carrying Case


Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for Kusam-Meco 3-5/6 Digits 6000 Counts TRMS Digital Insulation Multimeter (24 Functions 79 Ranges), KM 878
SensingAC, True RMS
Display3-5/6 Digits 6000 Counts Backlight LCD Display
PolarityAutomatic
Update Rate5 Per Second Nominal
61 Segments Analog Bar Graph60 Per Second Max
Power Supply4 x r Alkaline AA Batteries
Power Consumption4.5mA Typical Except: ACV +Hz & VFD ACV +Hz: 7.0mA
Operating Temperature-10oC ~ 40oC
Pollution Degree2
IP RatingIP40
Storage Temperature-20oC ~ 60oC, < 80% R.H. (With Battery Removed)
AltitudeOperating Below 2000m
Low Battery4.6V
APO TimingIdle For 20 Minutes
APO Consumption50μA Typical
Dimension (LxWxH)208 x 103 x 64.5 mm