Kusam-Meco 4 Digit / 10,000 Counts Intrinsically Safe TRMS Digital Multimeter With PC Interface, KM822EX
Roll over the image to zoom in
Key Features
- Product Type: Multimeter
- Weight: 635 g
- Operating Temperature: 0°C - 45°C
- Pollution degree: 2
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹1,27,440 (Incl. of all taxes)
₹1,08,000 + ₹19,440 GST (18%)
MRP was MRP ₹1,35,000
Save 20%
3 Business Days
1
90303390
Download Kusam-Meco CatalogueNot available
Highlights
The approved explosive protection rating of this equipment is suitable for use in Zone 1 hazardous areas. Group I (coal mines) underground & Group II (surface).
Features & Benefits:
- Splash / Drop Proof
- 1000V AC / DC
- USB Interface
- Dual Display
- Backlit Display
- Intrinsically Safe
- Beep-JackAudible & Visible Input Warning
- Relative Zero Mode
- PC Interface Capability
- Data Hold
- Ex Rating: Ex ib IIA T4 Gb
- 1A / 1kV (IR10kA)for mA & mA (1000V HRC Fuse)
- 11A / 1kV (IR20kA) for A (1000V HRC Fuse)
- DC Voltage Basic Accuracy 0.08%
- 4 Digit 10,000 counts large easy to read Backlight LCD display
- Fast Measurements, 5/sec; Fully Auto-Ranging
- Logic & Line Level Frequency
- Logic Level Duty Cycle Readings & Diode Tester
- Fast Audible Continuity
- Auto Power Off
Marking on Meter:
- MTEx-MS/19.0358 X
- Ex Rating: Ex ib IIA T4 Gb
- Ex ib I Mb.
- IP 64
Safety:
- Double insulation per IEC/UL/EN61010-1 Ed.3.0 IEC/EN61010-2-030 eD. 1.0, IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 & CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0 to Category IV 1000V AC & VDC.
- Transient Protection: 12 kV (1.2/50ms surge)
- Terminals (to COM) Measurement Category - V / A / mAµA: Category IV 1000VAC & DC
- Overload Protection: µA & mA - : 0.44A/1000V AC/DC, IR 10kA, F Fuse / A: 11A/1000Vac & Vdc, IR 20kA or better, F Fuse / V: 1100V DC/AC rms / mV, ohms & Others : 1000V DC/AC rms
- EMC: Meets EN61326-1:2006 Capacitance function is not specified Other function ranges - Total Accuracy = Specified Accuracy + 100 dgts Performance above 3V/m is not specified.
Package Content:
- Test lead pair
- Battery installed
- User Manual
- Carrying case
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| Operating Temperature | 0°C - 45°C |
|---|---|
| Pollution degree | 2 |
| Low Battery | Below approx 7V |
| Sensing | AC True RMS |
| Altitude | Operating below 2000 m |
| Power Consumption | 5mA Typical |
| APO Timing | Idle for 30 minutes |
| APO Consumption | 50mA typical |
| Power Supply | 1 x 9V battery |
| Display | 9999 Counts (ACV, DCV, Hz & nS) / 6000 Counts : mV, mA, mA, A, Ohm & Capacitance |
| Update Rate | Digital Display - 5 per second nominal / 41 Segments Bar-graph - 60 per second max |
| Relative Humidity | Max. 80% R.H. for Temperature up to 31°C decreasing linearly to 50% R.H. at 45°C |
| Storage Temperature | -20°C to 60°C, <80% R.H. (with battery removed) |
| Temperature Coefficient | nominal 0.15 x ( specified accuracy)/°C @ (0°C ~ 18°C or 28°C ~ 45°C) or otherwise specified |
| Dimension (LxWxH) | 208 x 103 x 64.5 mm with holster |