Key Features

  • Product Type: Process Calibrators
  • Weight: 0.5 kg
  • DC Voltage Range: 0 to 50mV/500mV
  • DC Voltage Resolution: 1μV
  • DC Voltage Accuracy: ±0.02%
See all product information

ToolBuy Benefits

₹92,888 (Incl. of all taxes)

₹78,719 + ₹14,169 GST (18%)

MRP was MRP ₹1,15,763

Save 32%



5 Business Days

1

9031

Download Product LeafletNot available
Download Metravi CatalogueNot available

Highlights

6 Digits, 0.2% Accuracy, Sources R, S, B, E, K, J, T, N types of thermocouples, PT-100, Cu-50, DC Voltage, DC Current, Resistance, Analogue Transducer, Frequency, Pulse Output and LOOP Power.

Features:

  • Source & Measured DC Voltage, Resistance, Thermocouple Temperature Detector, Resistance Temperature Detector.
  • Can use temperature detector with high Accuracy of ±0.2°C
  • It can be calibrated without open the cover of the calibrator
  • The Backlight and the power supply can be shut Off automatically
  • High Accuracy of 0.02% for measure and source. 6 digits for generated value and 5digits for measured value
  • Measure: DC voltage, resistance, thermocouple temperature detector, resistance temperature detector
  • Source: DC voltage, resistance, thermocouple temperature detector, resistance temperature detector
  • Measured Resistance and resistance temperature with 2-wire, 3-wire or 4- wire
  • Reference junction compensation automatically for thermocouple temperature measure and source. Temperature unit °C, °F
  • Can use temperature detector with high accuracy of ±0.2°C
  • The temperature and equivalent voltage or resistance or operating temperature can be displayed simultaneously on the large LCD
  • The keys for the generation functions and the measurement functions are separate from each other, and carefully designed the key layout, the each pairs of UP/DOWN keys are corresponding the each digit of the LCD
  • It can be calibrated without open the cover of the calibrator
  • The backlight and the power supply can be shut off automatically
  • Display: 6 Digits LCD with white backlight LED
  • DC Voltage : 0 – 50mV/500mV
  • Resolution : 1µV / 10µV, Accuracy : ±0.02%
  • Resistance : 0.00Ω to 550Ω
  • Resolution : 0.01Ω, Accuracy : ±0.05%
  • R Type Thermocouple : 0°C to 1767°C
  • Resolution : 1°C, Accuracy : ±1.5°C
  • S Type Thermocouple : 0°C to 1767°C
  • Resolution : 1°C, Accuracy : ±1.5°C
  • K Type Thermocouple : -100.0°C to 1372°C
  • Resolution : 0.1°C, Accuracy : ±0.8°C
  • E Type Thermocouple : -50.0°C to 850°C
  • Resolution : 0.1°C, Accuracy : ±0.9°C
  • J Type Thermocouple : -60.0°C to 1120°C
  • Resolution : 0.1°C, Accuracy : ±0.7°C
  • T type Thermocouple : -100.0°C to 400°C
  • Resolution : 0.1°C, Accuracy : ±0.7°C
  • N Type Thermocouple : -200.0°C to 1300.0°C
  • Resolution : 0.1°C, Accuracy : ±0.9°C
  • B Type Thermocouple : 600.0°C to 1820°C
  • Resolution : 1°C, Accuracy : 1.4°C
  • L –Type Thermocouple : -60°C to 900°C
  • Resolution : 0.1°C, Accuracy : 0.5°C
  • U Type Thermocouple : -100°C to 600°C
  • Resolution : 0.1°C, Accuracy : ±0.5°C
  • PT-100-385 : -200°C to 800°C
  • Resolution : 0.1°C, Accuracy : ±0.5°C
  • PT-200-385 : -200°C to 630°C
  • Resolution : 0.1°C, Accuracy : ±0.22°C
  • PT-500-385 : -200°C to 630°C
  • Resolution : 0.1°C, Accuracy : ±0.3°C
  • PT-1000-385 : -200°C to 630°C
  • Resolution : 0.1°C, Accuracy : ±0.4°C
  • Cu10 Sensor : -100°C to 260°C
  • Resolution : 0.1°C, Accuracy : ±2°C
  • Cu50 Sensor : -50°C to 150°C
  • Resolution : 0.1°C, Accuracy : ±0.5°C
  • Continuity : ≤50Ω Sound
  • Resolution : 0.01Ω, Accuracy : ±0.02%


Other Features:

  • Rate: 2 Readings per Second for DC Voltage, DC current, Resistance.
  • DCV: Normal Mode Rejection Ratio (NMRR) ≥ 60dB (at 50Hz or 60Hz) Common Mode Rejection Ratio (CMRR) > 120dB (at 50Hz or 60Hz)
  • Temperature Coefficient: 0.1 times the applicable accuracy specification per degree C for 5°C to 18° and 28° to 50°
  • The range of the internal temperature compensation sensor is from 0? to 40?, compensation error < ±0.5°C
  • Maximum voltage between VQHz terminal and COM terminal: 60 Vp-p


General Specifications:

  • Operating temperature and humidity, <80% at 0°C to 50°C (non-condensing) <70% at 40°C to 50°C
  • Storage temperature and humidity ≤ 90% at -25°C to 60°C (non-condensing)
  • Display and backlight, A dual, Liquid Crystal Display, White LED for backlight
  • Power Supply: 4×1.5AA-size alkaline batteries 4×1.2AA-size Ni-Hi batteries, AC adapter can charge Ni-Hi battery (Optional) Automatic Power-off: It's allowed set the Automatic Power-off time From 0 to 60 minutes.


Technical Specifications:

These specifications assume:
  • A 1-year calibration cycle
  • An operating temperature of 18°C to 28°C (64.4°F~82.4°F)
  • Relative humidity of 35% to 70% (non-condensing)
Accuracy is expressed as ± (percentage of set value + percentage of range)



What's Included In This Package:

  • Accessories
  • Test leads
  • Fuse

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for Metravi 6 Digit 0.2% Accuracy Universal Source Thermocouple Calibrator, 14+
ColourYellow-Black
DisplayBacklit LCD
DC Voltage Range0 to 50mV/500mV
DC Voltage Resolution1μV
DC Voltage Accuracy±0.02%
Resistance Range0ohm to 550ohm
Resistance Resolution0.01ohm
Resistance Accuracy±0.05%
Power SourceBattery Operated
Battery TypeAlkaline
Battery SizeAA
No of Batteries4

Shop By Related Categories