Kusam-Meco 3-5/6 Digits 6000 Counts Dual Display TRMS Digital Clampmeter With VFD & EF-Detection, KM 072
Roll over the image to zoom in
Key Features
- Product Type: Clamp Meters
- Weight: 186 g
- Display Digits: 3-5/6
- Display Counts: 6000
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹8,118 (Incl. of all taxes)
₹6,880 + ₹1,238 GST (18%)
MRP was MRP ₹8,600
Save 20%
3 Business Days
1
90303100
Download Kusam-Meco CatalogueNot available
Highlights
AmpTip™ low-current range calibrated at Jaw-tip for slim conditions for accurate readings. VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives
Features & Benefits:
- MAX/MIN/AVG Recording mode (Auto-ranging)
- Display Hold & Non-Contact EF-Detection (NCV)
- Probe-Contact EF-Detection
- Relative Humidity - Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C
- Temperature Coefficient - Nominal 0.15 x (specified accuracy) /° C @ (0 ° C - 18 ° C or 28 ° C - 40 ° C), or otherwise specified
- Low Battery - Below approx. 2.85V for Capacitance & Hz / Below approx. 2.5V for other functions
Safety:
- Double insulation per UL/IEC/EN61010-1 Ed. 3, IEC/EN61010-2-033 Ed.1, CAN/CSA C22.2 No. 61010-1 Ed. 3, IEC/EN61010-2-032 Ed.3 & IEC/EN61010-031 Ed. 1.1
- Measurement Category - CAT III 600V AND CAT IV 300V AC & DC
- E.M.C. - Meets EN61326-1: 2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11): DCA and DC+ACA Functions, in an RF field of 1V/m: Total Accuracy = Specified Accuracy + 20 digits at around 405MHz DCmA and Ohm Functions, in an RF field of 1V/m: Total Accuracy = Specified Accuracy + 25 digits / Other Functions, in an RF field of 3V/m: Total Accuracy = Specified Accuracy + 20 digits
- Overload Protection: Current & Hz functions via jaws : 600ADC/AAC rms at <400Hz / Voltage & 3-Phase Rotation functions via terminals : 660VDC/ 920VAC rms; Other functions via terminals : 600VDC/ VAC rms
- Pollution Degree: 2 / Rugged Fire retarded casing
- Transient Protection: 6.0kV (1.2/50ms surge)
- Rugged Fire retarded casing.
- LVD EN61010-1/61010-2-032/EN61010-2-033 to CAT III 600V & CAT IV 300V
Package Content:
- Test leads set
- Users Manual
- Battery & Carrying Case
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| Sensing | AC / True RMS |
|---|---|
| Jaws Opening Size & Conductor Diameter | 30 mm (Max.) |
| Display Digits | 3-5/6 |
| Display Counts | 6000 |
| Update Rate | 5 Per Second Nominal |
| Polarity | Automatic |
| Operating Temperature | 0°C to 40°C |
| Altitude | Operating below 2000 m |
| Storage Temperature | -20 °C ~ 60 °C, <80% R.H. (With Battery Removed) |
| Power Supply | Standard 1.5V AAA Size Battery X 2 |
| Power Consumption | Typical 4.3 mA |
| APO Timing | Idle For 32 Minutes |
| APO Consumption | Typical 5 μA |
| Dimension (LxWxH) | 217 x 76 x 37 mm |