Metravi 1000 V DC / AC Voltage Tester Analogue Multimeter, 5050E
Roll over the image to zoom in
Key Features
- Product Type: Multimeter
- Weight: 490 g
- Power Supply: R6P, AA, 1.5V Internal Batteries
- DC Voltage Range: 0 - 0.05 / 0.5 V / 2.5 V / 10 V / 50 V / 250 V / 1000 V
- AC Voltage Range: 0 - 0.05 V / 0.5 V / 2.5 V / 10 V / 50 V / 250 V / 1000 V
ToolBuy Benefits
- Secure Payments
- Order Tracking (opens in a new tab)
₹4,333 (Incl. of all taxes)
₹3,672 + ₹661 GST (18%)
MRP was MRP ₹5,400
Save 32%
5 Business Days
1
9030
Download Metravi CatalogueNot available
Highlights
The 5050E Analogue Multimeter measures AC/DC Voltage up to 1000V, T-RMS AC/DC Current up to 10A, Resistance up to 2000MΩ, Frequency up to 25kHz, Transistor Testing, Diode Testing, Audible Continuity testing and Overload Protection.
Features:
| Over-voltage category | CAT II 1,000V, CAT III 500V to ground potential. |
| Standard Environment | 23°C+3°C, less than 75% RH. |
| Temperature Ranges | 0°C to 40°C, 32°F to 104°F for Operating condition. -10°C to 50°C, 14°F to 122°F for Storage condition. |
| Humidity Scope | Operating condition less than 90% RH. Storage condition: less than 80% RH. |
| Operating altitude | Max. 2,000 m |
Whats Included In This Package:
- 1x Set of 1000V/10A class Test Leads
- 1x Safety ceramic-tube Fuse 0.5A/1000V on PCBA
- 1x Safety ceramic-tube Fuse 10A/1,000V on PCBA
- 2x R6P, AA, 1.5V Batteries
- 1x 6F22, NEDA1604, 9V
Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.
Specifications
| Power Supply | R6P, AA, 1.5V Internal Batteries |
|---|---|
| DC Voltage Range | 0 - 0.05 / 0.5 V / 2.5 V / 10 V / 50 V / 250 V / 1000 V |
| DC Voltage Range (Accuracy) | +4 % of FSD. at 0.05V Range, ±3 % of FSD. at other ranges |
| AC Voltage Range | 0 - 0.05 V / 0.5 V / 2.5 V / 10 V / 50 V / 250 V / 1000 V |
| AC Voltage Range (Accuracy) | ±4 % of FSD. Band width: 40 ~ 400 Hz |
| DC Current Range | 0 - 0.01 / 0.05 / 0.25 / 2.5 / 25 mA - 250 mA - 10 A |
| DC Current (Accuracy) | ±3 % of FSD, ±4 % of FSD. For 10A Range |
| AC Current Range | 0 - 0.01 / 0.05 / 0.25 / 2.5 / 25 mA - 250 mA - 10 A |
| AC Current Range (Accuracy) | ±4 % of FSD. Band width: 40 ~ 1,000 Hz |
| Resistance Range | 0 – 1 kOhm / 10 kOhm / 100 kOhm / 1 MOhm / 10 MOhm / 1000 MOhm |
| Resistance Range (Accuracy) | ± of ARC (Scale Length) |
| Frequency Range | 0.25 / 2.5K / 25K Hz |
| Frequency Range (Accuracy) | ±3 % of FSD |
| Transistor Check | hFE: 0-1000 |
| Diode Check | IF, IR, LI, LV |
| Continuity Check | < 200 Ohm, Beeper sounding |
| Length x Width x Height (mm) Including Holster | 158 x 103 x 38 |
| Certifications | CAT-III 500V, CAT-II 1000V, UL 1244, VDE 0411 |