Metravi 1000 V DC Voltage Tester Bench Type Multimeter With LCD Display, 45 T-RMS

Shop all Metravi

SKU: ME.EL.MU.00055

Model: 45TRMS

Roll over the image to zoom in


Key Features

  • Product Type: Multimeter
  • Weight: 1 kg
  • Power Supply: Mains Operated
  • DC Voltage Range: 0 - 200 mV / 2 V / 20 V / 200 V / 1000 V
  • AC Voltage Range: 0 - 200 mV / 2 V / 20 V / 200 V / 750 V
See all product information

ToolBuy Benefits

₹11,407 (Incl. of all taxes)

₹9,667 + ₹1,740 GST (18%)

MRP was MRP ₹14,216

Save 32%


Out of Stock

5 Business Days

1

90308990

Download Product LeafletNot available
Download Metravi CatalogueNot available

Highlights

This instrument is a high-performance, 4½ digits bench multimeter for measuring DC and AC Voltage, DC and AC Current, Resistance, Capacitance, eHz, hFE, Diodes and Continuity. The max. voltage measuring can up to 1000V DC or AC peak value, resolution can be 10µV and current measuring can up to 20A, it also has the function of polarity auto-change, back-lit display and directly reading.
For AC measuring it is performed by high accuracy RMS, has the feature of width measuring, and to get accurate RMS for AC flow of any wave shape.

  • Power supply: 220V/110V AC
  • Manual range
  • 4 1/2-digit large LCD display with back light(displaying range:75 x 40mm), max. reading: 19999
  • Voltage measurement up to 1000VDC and 750V AC
  • DC, AC current up to 20A
  • ACV frequency response: 50kHz
  • Frequency, Resistance, Capacitance measurement, Triode, Diode check and Continuity Test
  • Overload protection:250V rms
  • Operation environment: 0°C--40°C,<75% R.H


Features:

Accuracy ±(reading% + the lowest effective digit) preheating time: 30 min.
Temperature for accuracy guarantee:(235)°C, R.H<75%.

DC Voltage
Range Accuracy Resolution
200mV + (0.05% RDG + 3) 10uV
2V + (0.05% RDG + 3) 100uV
20V + (0.05% RDG + 3) 1mV
200V + (0.05% RDG + 3) 10mV
1000V + (0.1% RDG +5) 100mV
Input resistance: 10ΜΩ for all ranges
Overload protection: 200mV range: 250VDC or AC peak value
Other range: 1000VDC or AC peak value

AC Voltage
Range Input Frequency Accuracy Resolution
200mV 50Hz-50kHz + (0.8% RDG + 80) 10uV
2V 50Hz-20kHz + (0.8% RDG + 80) 100uV
20V 50Hz-20kHz + (0.8% RDG + 80) 1mV
200V 50Hz - 5kHz + (0.8% RDG + 80) 10mV
750V 50Hz - 400kHz + (1.0% RDG +50) 100mV
The input value for accuracy gurantee should be larger than 10% of range.
Input resistance: 2MS2 for all range.
Overload protection: 200mV range: DC or AC peak value
Other range: 1000V DC or AC peak value

DC Current
Range Accuracy Resolution
20mA + (0.35% RDG +10) 1μA
200mA + (0.35% RDG +10) 10μ?
2A + (0.8% RDG +10) 100μ?
20A + (0.8% RDG +10) 1μA
Max. input voltage drop: 200mV
Max. input current: 20A (wighin 15s)
Overload protection: 2A/250V fused, 20A/250V fused

AC Current
Range Input Frequency Accuracy Resolution  
200mA 50Hz-5kHz + (0.8% RDG+80) 10μA  
2A 50Hz-400Hz + (1.0% RDG +50) 100μ?  
20A 50Hz-400Hz + (1.0% RDG +50) 1mA  
Max. input voltage drop: 200mV
Max. input current: 20A (within 15s)
Overload protection: 2A/250V fused, 20A/250V fused

Resistance
Range Accuracy Resolution
200 Ω + (0.1% RDG +20) 0.01 Ω
2k Ω + (0.1% RDG + 5) 0.1 Ω
20k Ω + (0.1% RDG + 5) 1 Ω
200k Ω + (0.1% RDG + 5) 10 Ω
2M Ω + (0.1% RDG + 5) 100 Ω
20M Ω + (0.4% RDG + 5) 1k Ω
Open voltage: less than 3V
Overload protection: 250V DC or AC peak value

Capacitance
Range Accuracy Resolution
20nF +(3.5% +20) 1pF
2uF +(3.5% +20) 100pF
200uF +(5%+30) 10nF
Measuring frequency: approx. 400Hz
Overload protectrion: 36V DC or AC peak value

Frequency
Range Accuracy Resolution
20kHz +(1.0% +20) 0.1Hz
200kHz +(1.0% +20) 1Hz
Input sensitivity: 500mV rms
Overload protection: 250V DC or AC peak value (within 15s)

hFE Measuring
Range Displaying Test
hFE NPN or PNP 0-1000.0 Basic current is approx. 10mA, Vce is approx. 3V

Diode & Continuity Test
Range Accuracy Resolution
  The measuring value is the approx. value for forward voltage drop. when the resistance under tested is less then 702 +20 £2, buzzer sounds and display the approx. value. The open voltage is approx. 3V Forward DCA is approx. 1mA, backward DCV is less than 3V
Overload protection: 250V DC and AC peak value.

Please Note that Product may differ eg. colour, size from the product Image displayed on website. Kindly check the specifications provided to make better purchase decision. M.R.P Prices and specifications are subject to change without notice.

Specifications

Technical specifications for Metravi 1000 V DC Voltage Tester Bench Type Multimeter With LCD Display, 45 T-RMS
Power SupplyMains Operated
DC Voltage Range0 - 200 mV / 2 V / 20 V / 200 V / 1000 V
DC Voltage Range (Accuracy)±0.05 %
DC Voltage Resolution10μV to 100mV
AC Voltage Range0 - 200 mV / 2 V / 20 V / 200 V / 750 V
AC Voltage Range (Accuracy)±0.8 %
AC Voltage Resolution10μV to 100mV
DC Current Range0 - 20mA / 200mA / 2A / 20A
DC Current Range (Accuracy)±0.35 %
DC Current Resolution1μA to 1mA
AC Current Range0 - 200mA / 2A / 20A
AC Current Resolution10uA to 1mA
AC Current Range (Accuracy)±0.8 %
Resistance Range0 – 200Ohm / 2kOhm / 20kOhm / 200kohm / 2MOhm / 20MOhm
Resistance Range (Accuracy)±0.1 %
Resistance Resolution0.01Ohm to 1kOhm
Frequency Range0 - 20kHz / 200kHz
Frequency Range (Accuracy)±1.0 %
Frequency Resolution0.1Hz to 1Hz
Capacitance Range0 - 20nF / 2uF / 200uF
Capacitance Accuracy±3.5 %
Capacitance Resolution1pF to 10nF
PolarityAutomatic
hFE MeasuringhFE NPN or PNP
Length x Width x Height (mm)260 x 220 x 82

Shop By Related Categories